Hello, welcome HongTelecom
Huawei 2488H V5 server rear Panel Components

FusionServer 2488H V5 Rack Server

The FusionServer 2488H V5 is Huawei’s latest 2U, 4-socket (4S) rack server, ideal for virtualization, HPC, database, and SAP HANA. In a virtualization scenario, one FusionServer 2488H V5 reduces OPEX by about 32%* compared to two traditional 2U, 2S rack servers. 2488H V5 supports 4 Intel® Xeon® Scalable Processors in a 2U space, up to 48 DDR4 DIMMs (2,666 MT/s), and up to 25 x 2.5-inch hard drives for local storage (configurable with 8 NVMe SSDs). It incorporates patented technologies such as Dynamic Energy Management Technology (DEMT) and Fault Diagnosis & Management (FDM), and integrates Huawei’s eSight software for entire-lifecycle management, helping customers drive down OPEX and improve Return On Investment (ROI).
Figure 1 shows the 2488H V5 rear panel.
5

1

PCIe Slot 1

2

PCIe Slot 2

3

PSU socket

4

USB 3.0 port

5

GE electrical port

6

10GE optical port

7

Management network port

8

System serial port

9

VGA port

10

PCIe Slot (numbered 3 to 11 from left to right)

11

PSU 1

12

PSU 2

Port

Type

Quantity

Description

GE electrical port

Electrical port

2

The mainboard provides two GE electrical LOM ports and two 10GE optical LOM ports, and does not support other electrical and optical LOM ports.

NOTE:

  • 10GE optical ports do not support 10 Mbit/s or 100 Mbit/s networks and the rate cannot be forcibly set to 1000 Mbit/s.
  • GE electrical port does not support forcible rates or 10 Mbit/s and 100 Mbit/s networks.

10GE optical port

Optical port

2

VGA port

DB15

1

The VGA port is connected to a terminal, such as a monitor or KVM.

NOTE:

If cables are connected to the front and rear VGA ports at the same time, the display effect may be affected.

System serial port

RJ45

1

The serial port is used as the system serial port by default. You can set it as the iBMC serial port by using the iBMC command. This port is used for debugging.

Management network port

Ethernet port

1

The 1000 Mbit/s Ethernet port is used for server management.

USB port

USB 3.0

2

The USB ports allow USB devices to be connected to the server.

NOTE:

Before connecting an external USB device, check that the USB device functions properly. A server may operate abnormally if an abnormal USB device is connected.

PSU socket

1 or 2

Determine the number of PSUs based on actual requirements, but ensure that the rated power of the PSUs is greater than that of the server. When one PSU is used, Predicted PSU Status on the iBMC WebUI cannot be set to Active/Standby.

Figure 2 shows the indicators on the rear panel of a server.
6

1

Health indicator

2

UID indicator

3

Connection status indicator/Data transmission status indicator

4

Connection status indicator/Data transmission status indicator

5

Transmission rate indicator

6

Data transmission status indicator

7

Connection status indicator

8

PSU indicator

Indicator State Description
Two GE
electrical ports
Connection status
indicator/Data
transmission status
indicator
Steady green: The network port is properly connected.
Blinking green: Data is being transmitted.
Off: The network port is not connected.
Two 10GE
optical ports
Connection status
indicator/Data
transmission status
indicator
Steady green: The network port is properly connected.
Blinking green: Data is being transmitted.
Off: The network port is not connected.
Transmission rate
indicator
Steady green: The data transmission rate is 10 Gbit/s.
Steady yellow: The data transmission rate is lower than 10 Gbit/s.
Off: The network port is not connected.
Management
network port
Connection status
indicator
Steady green: The network port is properly connected.
Off: The network port is not connected.
Data transmission
status indicator
Blinking yellow: Data is being transmitted.
Off: No data is being transmitted.
UID indicator The UID indicator helps identify and locate a server.
You can turn on or off the UID indicator by pressing
the UID button or remotely running a command on
the iBMC CLI.
Steady blue/Blinking blue: The server is being located.
Off: The server is not being located.
Health indicator Steady green: The server is operating properly.
Blinking red at 1 Hz: A major alarm has been
generated on the server.
Blinking red at 5 Hz: A critical alarm has been
generated on the server.
PSU indicator Steady green: The power input and output are normal.
Steady orange: The input is normal, but no power
output is supplied due to overheat protection,
overcurrent protection, short circuit protection, output
overvoltage protection, or some component failures.
Blinking green at 1 Hz:
The input is normal, the server is standby, and the
PSU is in MV6 mode. (The output voltage is 6.7 V.)
The input is overvoltage or undervoltage.
The PSU is in deep hibernation mode.
Blinking green at 4 Hz: under online firmware upgrade.
Off: No AC power is supplied.

OceanStor-Dorado5000-V3-01_
HUAWEI FusionServer 2488H V5 Rack Server specifications :

Form Factor 2U rack server
Processors 2 or 4 Intel® Xeon® Scalable Processors of up to 205W
Memory 48 DDR4 DIMM slots, with memory speeds of up to 2,666 MT/s
Internal Storage Supports the following hard drive configuration options:
8 x 2.5-inch SAS/SATA HDDs on the front
25 x 2.5-inch SAS/SATA HDDs on the front
24 x 2.5-inch SAS/SATA HDDs on the front
8 x 2.5-inch NVMe SSDs and 16 x 2.5-inch SAS/SATA HDDs on the front
Supports flash storage:
2 M.2 SSDs (Note 1)
RAID Support Supports RAID 0, 1, 5, 6, 10, 50, or 60
Supports a supercapacitor for cache power-off protection
Supports functions such as RAID state transition and RAID configuration memory
LOM Network Ports 2 x GE + 2 x 10 GE ports
PCIe Expansion Up to 11 PCIe 3.0 slots:
1 PCIe x8 slot that provides x4 interfaces
7 PCIe x8 slots
3 PCIe x16 slots
Fan Modules 4 hot-swappable fan modules, providing protection against single-fan failures
Power Supply Units 2 hot-swappable PSUs, with support for 1+1 redundancy. The following PSUs are supported:
2,000W AC PSUs (Note 2)
1,500W AC PSUs (power supply: 100V AC to 127V AC; 200V AC to 240V AC;
or 190V DC to 300V DC)
900W AC PSUs (power supply: 100V AC to 240V AC; or 190V DC to 290V DC)
1,200W DC PSUs (power supply: -38.4V DC to -72V DC)
Management Based on the Huawei iBMC chip, provides comprehensive management features
such as fault diagnosis, automated O&M, and hardware security hardening;
supports mainstream standard interfaces such as Redfish, SNMP, and IPMI 2.0,
facilitating integration with third-party management software; provides remote
management interfaces based on HTML5 and VNC KVM; supports features
such as Smart Provisioning and Agentless to simplify management.
Optionally configured with Huawei eSight management software; provides advanced
management features such as stateless computing, batch OS deployment, and
automated firmware upgrade, enabling smart and automated entire-lifecycle management.
Operating
Temperature
5°C to 45°C (41°F to 113°F), compliant with ASHRAE Classes A3 and A4
Notes Note 1: The feature supporting 2 M.2 SSDs is planned for release in Q2, 2018.
Note 2: The 2,000W PSU is planned for release in Q2, 2018.