Huawei Rack server RH2288H V3 components

FusionServer RH2288H V3 Rack Server
New-generation 2U, 2-socket rack server delivers high performance and large storage capacity, and scalability. Ideal choice for Internet, Big Data, cloud computing, and telecom services.
huawei RH2288H V3 (1)
RH2288H V3 components
2-18

1 I/O module 1 2 PCIe card on a riser card
3 PCIe card on the mainboard 4 I/O module 2
5 Internal cable guide 6 Chassis
7 Power supply unit (PSU) 8 PSU backplane
9 Air duct 10 Supercapacitor tray
11 Supercapacitor 12 Hard disk backplane
13 Right mounting ear 14 Left mounting ear
15 Hard disk 16 Fan module
17 Fan module bracket 18 Heat sink
19 CPU installation tool 20 DIMM
21 CPU 22 RAID controller card
23 (optional) Trusted platfprm module (TPM) 24 Mainboard
25 SATADOM 26 Dual-SD card module
27 SD card 28 LAN on motherboard (LOM)
 
 
No.
Component Description
1 I/O module 1 Supports the following configurations:
One standard full-height full-length PCIe 3.0 x16 slot,
one standard full-height full length PCIe 3.0 x8 slot, and
one standard full-height half-length PCIe 3.0 x8 slot
(bandwidth of the three slots: PCIe 3.0 x8)
Two standard full-height full-length PCIe 3.0 x16 slots
(bandwidth of one of them:PCIe 3.0 x8)
Two 2.5-inch hard disk slots
Two 3.5-inch hard disk slots
2 PCIe card on a riser card The RH2288H V3 supports two types of riser cards:
Riser card 1 with three PCIe 3.0 x8 slots for the following devices:
One full-height full-length PCIe 3.0 x16 card (bandwidth: PCIe 3.0 x8)
One full-height full-length PCIe 3.0 x8 card
One full-height half-length PCIe 3.0 x8 card
Riser card 2 with two PCIe 3.0 x16 slots for the following devices:
One full-height full-length PCIe 3.0 x16 card
One full-height full-length PCIe 3.0 x16 card (bandwidth: PCIe 3.0 x8)
The two types of riser cards can be installed on both
I/O modules 1 and 2.
3 PCIe card on the
mainboard
Two half-height half-length PCIe 3.0 x8 slots for standard PCIe cards
4 I/O module 2 Supports the following configurations:
One standard full-height full-length PCIe 3.0 x16 slot, one standard full-height
full-length PCIe 3.0 x8 slot, and one standard full-height half-length
PCIe 3.0 x8 slot (bandwidth of the three slots: PCIe 3.0 x8)
Two standard full-height full-length PCIe 3.0 x16 slots (bandwidth of one of them:
PCIe 3.0 x8)
Two 2.5-inch hard disk slots
Two 3.5-inch hard disk slots
5 Internal cable
guide
Enables neat cabling.
6 Chassis Houses all components.
7 PSU Two hot-swappable PSUs in 1+1 redundancy mode.
Choose the following types of PSUs based on the input power:
AC PSUs: 100 V to 240 V AC
DC PSUs: –48 V to –60 V DC
240 V high-voltage direct-current (HVDC) PSUs: 192 V to 288 V DC
380 V HVDC PSUs: 260 V to 400 V DC
NOTICE:
The PSUs provide short-circuit protection. The PSUs that support dual input live
wires provide double-pole fuses.
8 PSU backplane Connects PSUs to the mainboard.
9 Air duct Facilitates chassis ventilation.
10 Supercapacitor
tray
Secures a supercapacitor for a RAID controller card.
11 Supercapacitor Protects RAID cache data from power failures for controller car
using LSI SAS2208, LSI SAS3108, or SP435 (PM8060)
chips on the RH2288H V3.
12 Hard disk
backplane
Supplies power to hard disks and provides data transmission channels.
The RH2288H V3 supports hard disk backplanes for
connecting to 8 x 2.5-inch,8 x 3.5inch, 12, 12 (including
four NVMe PCIe SSDs), 12 (including twelve NVMe
PCIe SSDs), 24, 25 hard disks respectively.
13 Right mounting ear Fixes the server in the cabinet and integrates a fault
diagnosis LED, health indicator,
UID button/indicator, and power button/indicator.
14 Left mounting ear Fixes the server in the cabinet and provides two USB 2.0
ports and four network port link status indicators.
15 Hard disks Store data.
Hard disks are hot-swappable.
16 Fan modules Dissipate server heat and support hot swaps.
If fan modules are in full configuration, the server tolerates
the failure of a single fan module and supports fan speed
adjustment by area, maintaining optimal heat dissipation.
17 Fan module
bracket
Secures a fan module.
18 Heat sinks Dissipate heat from CPUs. Each CPU is configured with one heat sink.
19 CPU installation
tool
When configuring a V3 series CPU, avoids twisted pins during
CPU installation and removal after the tool clips onto
the CPU properly.
20 DIMMs DIMM type: DDR4 registered dual-line memory
modules (RDIMMs) or load-reduced DIMMs (LRDIMMs)
Maximum number of DIMMs: 24
Maximum memory capacity: 3072 GB
Capacity per DIMM: 8 GB, 16 GB, 32 GB, 64 GB, or 128 GB
Memory speed: DDR4 1866 MT/s, 2133 MT/s, or 2400 MT/s
21 CPUs Process data.
To provide powerful data processing functions, the RH2288H V3
has CPUs integrated with memory controllers and PCIe
controllers. The server supports the following CPU configurations:
Intel® Haswell-EP® E5-2600 v3 4-core, 6-core, 8-core, 10-core,
12-core, 14-core,16-core, and 18-core CPUs with
up to 145 W power.
Intel® Broadwell-EP® E5-2600 v4 4-core, 6-core, 8-core, 10-core,
12-core, 14-core,16-core, 18-core, 20-core, and 22-core CPUs with
up to 145 W power.
NOTE:
The RH2288H V3 supports a maximum of two E5-2600 v3 series CPUs or
two E5-2600 v4 series CPUs.
22 RAID controller card Supported RAID controller card models:
SR320 or SR420:
Uses the LSI SAS2208 chip.
Supports RAID 0, 1, 10, 5, 50, 6, and 60.
Supports a supercapacitor for power failure protection.
SR120:
Uses the LSI SAS2308 chip.
Supports RAID 0, 1, 1E, and 10.
Does not support power failure protection.
SR130:
Uses the LSI SAS3008 chip.
Supports RAID 0, 1, 10, and 1E.
Does not support power failure protection.
SR430C:
Uses the LSI SAS3108 chip.
Supports RAID 0, 1, 10, 5, 50, 6, and 60.
Supports a cache of 1 GB or 2 GB.
Supports a supercapacitor for power failure protection.
SR135:
Uses the PM8068 chip.
Supports RAID 0, 1, 10, and 5.
Does not support power failure protection.
These RAID controller cards support RAID level migration and RAID configuration memory.
23 TPM (optional) Complies with the Trusted Computing Group (TCG) standards
Protects the platform from viruses or unauthorized operations.
24 Mainboard Integrates basic components, including the BIOS chip, Platform
Controller Hub (PCH) chip, and PCIe slots, and provides
CPU sockets and slots for DIMMs and othercomponents.
Integrates the SM750 display chip and provides 32 MB display
memory. The maximum resolution is 1920 pixels x 1200 pixels at
60 Hz with 16 M colors.
NOTE:
After a dedicated graphics card driver is installed, only Windows
Sever 2012, Windows Sever 2012 R2, Windows Server 2016
can support the resolution of 1920 pixels x 1200
pixels while other OSs only support the maximum
resolution supported by the built-in drivers.
25 SATADOM A quick memory storage media unit that features high energy
efficiency and stability. It can be a SATA SSD or SATADOM electrical hard disk.
SATADOMs use flash memory to store data. Currently, NAND f
lash memory is mostly usedin the industry. NAND flash memory
stores electrons on the floating gate to store data.However,
electrons frequently passing through the floating gate will weaken
the gate’s ability to store electrons and eventually make the
gate unable to store electrons. This problem is common to NAND flash memory.
The amount of service data to be written
needs to be assessed to prevent component failures.
NOTE:
If the SoftRAID function is enabled on the server, the STATADOM supports SoftRAID,
which supports RAID 0 and RAID 1.
A SATADOM can be used only as a boot disk for Linux OSs.
SATADOMs have weak endurance and cannot be used as data storage devices.
Use enterprise-level HDDs or SSDs to replace SATADOMs for data storage when
frequent data erase operations are involved.
Installing write-intensive service software on SATADOMs will accelerate the write life
consumption and result in perpetual damage of SATADOMs. SATADOMs cannot be
used for such services.
SATADOMs cannot be used in cache scenarios.
SATADOMs and built-in driver SATA ports are exchangeable.
The RH2288H V3 supports two SATADOMs. The mappings between the physical
positions and the port numbers in the BIOS are as follows: SATA1 – PORT4;
SATA2 – PORT5.
26 Dual-SD card module Provides two SD card slots. Each slot supports an SD card of up to 32 GB.
SD cards can be used as the boot media of the server.After the iBMC
initialization is complete, two SD cards are configured as a RAID 1 array
when being detected. You can view the information about the SD cards
and RAID 1 array on the iBMC WebUI by choosing System Info > Other,
but cannot modify the configuration or manually configure them.
27 SD card SD cards use flash memory and SPIs to store data. Currently, NAND flash memory is
mostly used in the industry. NAND flash memory stores electrons on the floating gate to
store data. However, electrons frequently passing through the floating gate will weaken
the gate’s ability to store electrons and eventually make the gate unable to store electrons.
This problem is common to NAND flash memory. The amount of service data to be written
needs to be assessed to prevent component failures.
NOTE:
An SD card can be used only as a boot device for OSs.
SD cards have weak endurance and cannot be used as data storage devices. Use
enterprise-level HDDs or SSDs to replace SD cards for data storage when frequent
data erase operations are involved.
Installing write-intensive service software on SD cards will accelerate the write life
consumption and result in perpetual damage of SD cards. SD cards cannot be used
for such services.
SD cards cannot be used in cache scenarios.
28 LOM Supported configurations:
One GE NIC with two or four GE ports, or one 10GE NIC with two 10GE electrical or
optical ports. Both NICs support the Network Controller Sideband Interface (NC-SI).
One IB NIC with one or two 56G IB optical ports. The NIC does not support NC-SI.

huawei RH2288H V3 (2)
 

Leave a Reply

Close Menu
×
×

Cart